Integrated elevated strawberry growing-system package for preliminary planning of approximately 1,000 m². It can combine formed gutters, galvanized support frames, cocopeat grow bags, dripper-line interfaces, drainage outlets and return-water collection. Row spacing, working height, slope, plant density, saturated load and final quantities are engineered around the greenhouse, cultivar and production target before quotation.
Coordinated irrigation and fertigation package for preliminary planning of a greenhouse or net-house area around 1,000 m². The selectable scope includes pump, media or disc filtration, fertilizer stock tanks, dosing pumps, EC and pH monitoring, safety interlocks, valves, zone manifold and distribution interfaces. Final capacity and component selection follow water analysis, crop demand, hydraulic zones, available pressure and the required automation level.
Roll-formed galvanized C-profile for greenhouse vertical framing, secondary supports and compatible construction details. The 50 mm width and 1.5 mm sheet thickness provide a defined procurement basis; final length, hole pattern, galvanizing class, spacing and structural duty must be checked against the approved greenhouse drawings and site loads.
Large galvanized fixing washer for distributing fastener load across greenhouse polycarbonate and compatible cladding details. Manufactured to a 50 mm outside diameter, 2 mm steel thickness and 8 mm centre hole procurement basis. Use with the approved screw, sealing washer and support profile, leaving the thermal-movement allowance specified for the sheet system.
Galvanized round drive tube for transmitting motion through greenhouse rack-and-pinion roof or side-vent systems. The 32 mm outside diameter and 2 mm wall specification must be coordinated with couplings, bearing supports, pinions, motor torque and vent length. Straight alignment and correctly spaced supports are essential to prevent binding and uneven opening.
Clear UV-protected U-profile for protecting the open ends of compatible multiwall polycarbonate sheets. It supports a clean cladding edge while reducing dirt, insects and physical damage at the flutes. Use with the specified vent or sealing tape and drainage orientation; match the profile to sheet thickness before ordering.
Take-off connector for forming a sealed branch from a polyethylene submain into a 16 mm drip lateral. Install through a correctly sized punched hole with the supplied rubber grommet, then pressure-test the connection before covering or operating the zone.
Reusable figure-eight closure for folding and sealing the end of a 16 mm dripline while preserving easy access for flushing. Match the closure to the lateral outside diameter and reopen each line during scheduled system maintenance.
Ninety-degree polypropylene compression elbow for changing direction in 20 mm polyethylene irrigation pipe. Cut the pipe square, seat it fully beyond the internal seal and confirm pressure rating and pipe outside diameter before installation.
Online pressure-compensating emitter designed to maintain a nominal four-litre-per-hour discharge across a defined pressure range. Use filtration appropriate to the emitter passage and verify uniformity, operating pressure and lateral length during commissioning.
Complete stake-dripper assembly for delivering water and nutrient solution directly to pots, grow bags and hydroponic slabs. Secure the arrow close to the root zone, keep microtube runs consistent and flush manifolds before connecting the outlets.
Flexible polyethylene microtube for connecting manifolds and online emitters to arrow drippers or pot stakes. Keep runs as equal and short as practical, avoid sharp bends and confirm compatibility with the selected barb fittings and operating pressure.
Low-flow mini sprinkler for uniform nursery, propagation and greenhouse irrigation. Layout depends on mounting height, pressure, spacing and overlap; use an anti-drain valve where elevation changes could empty laterals between irrigation cycles.
Four-nozzle fine-mist assembly for greenhouse humidification, propagation and evaporative cooling. Final nozzle spacing and cycle timing must follow water quality, pressure, target humidity and ventilation rate; fine filtration is essential to reduce blockage.
Centrifugal pre-filter for removing heavy sand and mineral particles from borewell irrigation water before disc or screen filtration. Size the unit by design flow and pressure loss, and purge the collection chamber according to the measured sediment load.
Normally closed electric control valve for automated irrigation zones, greenhouse blocks and fertigation manifolds. Confirm voltage, flow range, pressure, connection standard and chemical compatibility, and install with upstream filtration and manual isolation.
Straight barbed coupling for joining two 16 mm polyethylene drip laterals during installation or repair. Cut both pipe ends square, push them fully over the barbs and verify the joint under normal operating pressure.
Three-way barbed tee for branching 16 mm drip irrigation laterals into crop rows, benches or planting zones. Confirm tube dimensions and keep branch lengths within the hydraulic limits of the emitter and available pressure.
Compact quarter-turn valve for manually isolating individual 16 mm drip laterals or small irrigation sections. Install where the handle remains accessible and flush the line before commissioning to protect the internal passage.
Male-threaded start connector for transitioning from a manifold, valve or threaded outlet to 20 mm polyethylene irrigation pipe. Confirm thread standard, use an irrigation-compatible seal and pressure-test the assembled connection.
Combination valve designed to discharge large air volumes during filling, release accumulated air under pressure and admit air while the irrigation main drains. Install vertically at hydraulic high points with a service isolation valve.
Inline meter for tracking irrigation-zone flow, verifying system performance and supporting water-use records. Select the body size and measuring range from normal and peak flow, provide the required straight pipe lengths and install in the specified orientation.
Non-return valve for limiting reverse flow through irrigation mains, pump discharges and fertigation assemblies. Verify the flow direction, pressure rating and chemical compatibility, and leave access for inspection and cleaning.
Glycerin-filled gauge for monitoring irrigation pressure at pumps, filters, regulators and zone manifolds. Choose a range that keeps normal pressure near the middle of the scale and use an isolation cock or snubber where required.